Model : AQ-9901SD
SD Card real time data recorder, Patent CO2, CO, O2, Humidity, Temp. , 6 in 1
FEATURES
FEATURES
* Real time recorder, save the data into the SD memory Operating Less than 80% R.H.
card and can be down load to the Excel, extra software Humidity
is no need. User can make the further data or graphic Weight 350 g/0.77 LB.
analysis by themselves. under the Excel software. Dimension Meter 177 x 68 x 45 mm
* At the same time, the SD memory card can record 3 Humidity 197 mm in length.
probe’s data ( %RH/CO2/O2/Temp. or probe
%RH/CO2/CO/Temp. ) along with the time information CO2 probe 190 x 38 x 28 mm
into the one Excel file at the same time. O2 probe 150 x 38 x 38 mm
* Manual datalogger is available, during execute the CO probe 150 x 38 x 38 mm
manual datalogger function, it can set the different Accessories Instruction manual…………………………1 PC
location no. ( position 1 to position 99 ). Included Hard carrying case, CA-08………………..1 PC
* Air quality measurement application, multi-function : CO2 probe………………………………… 1 PC
CO2 (Carbon dioxide ), CO ( Carbon monoxide ), O2 Humidity probe……………………………. 1 PC
( Oxygen in air ), Humidity, temperature measurement. O2 probe……………………………………. 1 PC
* CO2 range : 0 to 4,000 ppm x 1 ppm. CO probe…………………………………… 1 PC
* O2 range : 0 to 30.0 % x 0.1 %. Optional SD memory card ( 2 GB )
* CO range : 0 to 1,000 ppm x 1 ppm. Accessories AC to DC 9V adapter.
* Humidity range: 10 to 95 %RH. USB cable, USB-01.
* Dew point Temp. and Wet bulb Temp. measurement. RS232 cable, UPCB-02.
* Temp. range : 0 to 50.0 ℃, ℃/℉. Data Acquisition software, SW-U801-WIN.
* CO2 sensor : NDIR, long term reliability.
* CO, O2 sensor : Galvanic cell type. ELECTRICAL SPECIFICATIONS (23±5 ℃)
* Humidity sensor : Precision capacitance sensor
* Alarm setting with the beeper sound output. CO2 ( Carbon dioxide )
* Sampling time for data recorder is 2 seconds to 8 hours.
* Complete set with 4 probes : Range 0 to 4,000 ppm
CO2/Temp. probe, O2/Temp. probe, CO/Temp. probe, CO2 Resolution 1 ppm
Humidity/Temp. probe, main meter and the hard carrying ( Carbon Accuracy ± 40 ppm
case. dioxide ) * ≦1,000 ppm.
* Separate probe, easy for remote measurement. ± 5% of reading
* Meter can cooperate with 2 GB to 16 GB SD card, SD 23 ± 5 ℃. * > 1,000 ppm ≦ 3,000 ppm.
card is optional. ± 250 ppm typically
* RS232/USB computer interface.