2803 IN (Ranges: 0.5kV, 1kV, 2.5kV, 5kV)
FEATURES |
● Microprocessor-controlled. ● Four insulation test voltages. ● Insulation resistance; auto ranging on all ranges. ● Bargraph indicates test voltage; rise and decay can be observed during tests. ● Visual and audible warning if external voltage is present. ● EnerSave™ feature to extend battery life. ● 2 Lines × 16 characters large LCD. ● Low battery consumption. ● Low battery indicator. ● Overload protection. ● Auto-off. ● Show test time duration (up to 99.9s) for easy comparison. ● EEPROM calibration. ● Built-in carry case and test leads in separate pouch. |
Digital (1kV up) H.V. Insulation Tester
2804 IN (Ranges: 1kV, 2.5kV, 5kV, 10kV)
FEATURES |
● Microprocessor-controlled. ● Four insulation test voltages. ● Insulation resistance; auto ranging on all ranges. ● Bargraph indicates test voltage; rise and decay can be observed during tests. ● Visual and audible warning if external voltage is present. ● EnerSave™ feature to extend battery life. ● 2 Lines × 16 characters large LCD. ● Low battery consumption. ● Low battery indicator. ● Overload protection. ● Auto-off. ● Show test time duration (up to 99.9s) for easy comparison. ● EEPROM calibration. ● Built-in carry case and test leads in separate |
Digital (1kV up) H.V. Insulation Tester
4103 IN (Ranges: 0.5kV, 1kV, 2.5kV, 5kV)
FEATURES |
● Microprocessor-controlled. ● Four insulation test voltages. ● Insulation resistance; auto ranging on all ranges. ● Measures insulation time test. ● Bargraph indicates test voltage; rise and decay can be observed during tests. ● Visual and audible warning if external voltage is present. ● EnerSave™ feature to extend battery life. ● 2 Lines × 16 characters large LCD. ● Low battery consumption. ● Low battery indicator. ● Overload protection. ● Auto-off. ● Show test time duration (up to 99.9s) for easy comparison. ● EEPROM calibration. |
Digital (1kV up) H.V. Insulation Tester
4104 IN (Ranges: 1kV, 2.5kV, 5kV, 10kV)
FEATURES |
● Microprocessor-controlled. ● Four insulation test voltages. ● Insulation resistance; auto ranging on all ranges. ● Measures insulation time test. ● Bargraph indicates test voltage; rise and decay can be observed during tests. ● Visual and audible warning if external voltage is present. ● EnerSave™ feature to extend battery life. ● 2 Lines × 16 characters large LCD. ● Low battery consumption. ● Low battery indicator. ● Overload protection. ● Auto-off. ● Show test time duration (up to 99.9s) for easy comparison. ● EEPROM calibration. |
Digital (1kV up) H.V. Insulation Tester
6210A IN (Ranges: 0.5kV, 1kV, 2.5kV, 5kV)
FEATURES |
● Microprocessor-controlled. ● Four insulation test voltages. ● Insulation resistance; auto ranging on all ranges. ● Bargraph indicates test voltage; rise and decay can be observed during tests. ● Visual and audible warning if external voltage is present. ● Fully protected: crow bar. ● Carry case. ● EEPROM calibration. |
Digital (1kV up) H.V. Insulation Tester
6211A IN (Ranges: 1kV, 2.5kV, 5kV, 10kV)
FEATURES |
● Microprocessor-controlled. ● Four insulation test voltages. ● Insulation resistance; auto ranging on all ranges. ● Bargraph indicates test voltage; rise and decay can be observed during tests. ● Visual and audible warning if external voltage is present. ● Fully protected: crow bar. ● Carry case. ● EEPROM calibration |
Digital (1kV up) H.V. Insulation Tester
6212A IN (Ranges: 0.5kV to 10kV 0.5kV increment steps)
FEATURES |
● Microprocessor-controlled. ● 2 ×16 characters; large intelligent LCD module. ● 20 Insulation test voltages 500V, 1kV, 1.5kV, 2kV, 2.5kV, 3kV, 3.5kV, 4kV, 4.5kV, 5kV, 5.5kV, 6kV, 6.5kV, 7kV, 7.5kV, 8kV, 8.5kV, 9kV, 9.5kV, 10kV. ● Ener-Save™ feature to extend battery life. ● Bargraph indicates test voltage; rise and decay can be observed. ● Visual and audible warning if external voltage is present(>500Vac or Vdc.) ● Insulation resistance; auto-ranging on all ranges. ● Overload protection. ● Low battery indicator (read time battery voltage measurement). ● Measures insulation time duration of the test. ● Low battery consumption. ● Better than 10% accuracy on all ranges. ● Auto-off. |
Digital (1kV up) H.V. Insulation Tester
6213A IN (Ranges: 0.5kV to 10kV 0.5kV increment steps)
FEATURES |
● Microprocessor-controlled. ● 2 ×16 characters; large intelligent LCD module. ● 20 Insulation test voltages 500V, 1kV, 1.5kV, 2kV, 2.5kV, 3kV, 3.5kV, 4kV, 4.5kV, 5kV, 5.5kV, 6kV, 6.5kV, 7kV, 7.5kV, 8kV, 8.5kV, 9kV, 9.5kV, 10kV. ● Ener-Save™ feature to extend battery life. ● Bar-graph indicates test voltage; rise and decay can be observed. ● Visual and audible warning if external voltage is present (>500Vac or Vdc.) ● Insulation resistance; auto-ranging on all ranges. ● Overload protection. ● Low battery indicator (read time battery voltage measurement). ● Measures insulation time duration of the test. ● Low battery consumption. ● Better than 10% accuracy on all ranges. ● Auto-off. ● Calculates Dielectric Absorption Ratio (DAR) automatically. ● Calculates Polarization Index (PI) automatically. |
Digital H.V. Insulation Tester
7015 IN
FEATURES |
● Test Insulation Resistance up to 2 TΩ (2000GΩ). ● Short-circuit current up to 5mA. ● Microprocessor controlled. ● 30 insulation test voltages : 500V, 1kV, 1.5kV, 2kV, 2.5kV, 3kV, 3.5kV, 4kV, 4.5kV, 5kV, 5.5kV, 6kV, 6.5kV, 7kV, 7.5kV, 8kV, 8.5kV, 9kV, 9.5kV, 10kV, 10.5kV, 11kV, 11.5kV, 12kV, 12.5kV, 13kV, 13.5kV, 14kV, 14.5kV, 15kV ● AC/DC Voltmeter. ● PI (Polarization Index) indication. ● DAR (Dielectric Absorption ratio) indication. ● Auto-ranging on all insulation ranges. ● Backlight function. ● Bargraph indicates test voltage, rise and decay can be observed. ● Menu driven. ● Visual and audible warning if external voltage is present. (≥30Vac or ≥30Vdc). ● Auto-hold function to freeze the reading. ● Overload protection. ● Adjustment for testing time (duration) : 1~30 minutes. ● Auto-off. ● Calendar. ● Optical USB to RS-232 data transmission. ● 200 measurement results can be saved in the memory and recalled on the display. ● Safety standard: EN 61010-1 CAT IV 600V EN 61010-2-030 EN 61326-1 |
DIGITAL 5kV HIGH VOLTAGE INSULATION TESTER 5305IN
High contrast OLED display
• Microprocessor-controlled
• Tests insulation resistance up to 10 TΩ
• 4 Insulation test voltages: 500V, 1000V, 2500V, 5000V
• AC / DC Voltmeter
• Short-circuit current up to 5mA
• PI (Polarization Index) indication
• DAR (Dielectric Absorption Ratio) indication
• Auto-ranging on all insulation ranges
• Optical USB to RS-232 data transmission
• Well isolated from contact
• Well surge protected
• 2 built-in optical LEDs for data transfer
• Visual and audio warning if external voltage is present (≥30Vac or ≥30Vdc)
• Auto-hold function to freeze the reading
• Overload protection Adjustment for testing time (duration): 1~30 minutes
• Internal memory for data storage
• Indication of testing time (duration) for insulation measurement
• Auto-off function
• 200 measurement results can be saved in the memory and recalled on the display