HEAT INDEX WBGT METER Model : WBGT-2009
WBGT ( in/out door ), TG Temp., Humidity/ Air Temp.
Dew point Temp. Wet bulb Temp.
Soft carrying case
CA-05B. included
FEATURES
* Introduction : Optional * AC to DC 9V adapter. Wet bulb Temp.
WBGT ( wet-bulb globe temperature ) was developed Accessories * USB cable, USB-01. ℃ Range -21.6 ℃ to 50.0 ℃
as a monitoring basis at US military training camps * Data acquisition software,SW-U801-WIN. Resolution 0.1 ℃
and became widespread for the use in workplaces and * Excel data acquisition software, SW-E802. ℉ Range -6.9 ℉ to 122.0 ℉.
sports situation It is suggested in the international * Hard carrying case, CA-08, Resolution 0.1 ℉.
standard ISO 7243, OSHA ( US Occupation Safety ), Size : 370 x 310 x 115 mm. Remark : * Wet bulb display value is calculated from the
Japan Society for Occupational Health and the SMA ( Humidity/Air Temp. measurement automatically.
Sports Medicine Australia ) in establishing the * The Dew Point accuracy is sum accuracy value of
permissible heat exposure limits in health , sports or ELECTRICAL SPECIFICATIONS (23±5 ℃) Humidity & Air temperature measurement..
other physical activities. Wet bulb globe temperature ( WBGT )
* Measurement : WBGT value ( Indoor/Outdoor
HEAT INDEX WBGT METER Model No:WBGT-2010SDD
Soft carrying case
CA-05B. included
Description: |
* WBGT (wet-bulb globe temperature) was developed as a monitoring basis at US military training camps and became widespread for the use in workplaces and sports situation It is suggested in the international standard ISO 7243, OSHA (US Occupation Safety), Japan Society for Occupational Health and the SMA (Sports Medicine Australia) to establish the permissible heat exposure limits in health, sports or other physical activities. * Measurement : WBGT value (Indoor/Outdoor Wet bulb globe temperature), Black globe temperature, Humidity, Air temperature, Wet bulb temperature, Dew point Temp.. * Measurement function : 1. Wet bulb globe temperature (WBGT): Indoor : 0 oC to 59 oC. Outdoor : 0 oC to 56 oC. 2. Black globe Temp (TG) : 0 to 80 oC. 3. Air temperature (TA) : 0 to 50 oC. 4. Wet bulb temperature (WB) : -21.6 oC to 50.0 oC. 5. Humidity : 5 % to 95 % R.H.. 6. Dew point Temp. : -25.3 oC to 48.9 oC. * Unit : oC,oF, Resolution : 0.1 degree. * Adjustable WBGT alarm setting with buzzer sound output. * Control and monitor of physical activity in hot environment to limit the danger of heatrelated injuries. * Globe temperature measurement uses the Pt sensor, high accuracy. * Fast humidity measuring response time. * Direct measurement of the radiation effect with a brass black ball in 75 mm dia. * Real time SD memory card recorder, it is built-in Clock and Calendar. * Real time data recorder , sampling time set from 1 second to 3600 seconds. * Manual data record is available, can set the different position (location) No. (1 to 99). * Innovation and easy operation, computer is not need to setup extra software. After record the data, just take away the SD card from the meter and plug into the computer, the measured values with the time information(year/month/date/ hour/minute/second) can be downloaded to the Excel directly, then user can make the further data or graphic analysis by themselves. * SD card capacity : 1 GB to 16 GB. * Data hold, record max. and min. reading. * Power by UM3/AA (1.5 V) x 6 batteries or DC 9V adapter. * RS232/USB PC computer interface. * Complete set with the carrying case, SD card is optional. |
Sport/Weather meter ENVIRONMENT METER Model : SP-8001
9 in 1, Anemometer, Humidity meter, Light meter Light Meter, Pt 1000 Temp. ( optional )
FEATURES
* 9 in 1 professional environment instruments: Humidity/Temp.
1. Air velocty/Temp., 2. Humidity/Temp., 3. Light
4. CFM, CMM, 5. Dew point, 6. Wet bulb, Unit Range Resolution Accuracy
7. Wind chill, 8. Heat index, 9. Pt 1000 ohm Temp. % RH 10 to 95 %RH 0.1 %RH < 70% RH :
( optional ) ± 4 %RH
* Tiny bone shape with lightweight and small size case ≧70% RH :
design are suitable for handling with one hand. ± ( 4 %rdg +1.2 %RH)
* Wristlet design provides extra protection to the Temp. 0 to 50 ℃ 0.1 ℃ ± 1.2 ℃
instrument especially for user one hand operation. 32 to 122 ℉ 0.1 ℉ ± 2.5 ℉
* Low-friction ball bearing mounted wheel design
provides high accuracy at high and low air velocity. Light * auto range
* Exclusive photo diode and color correction filter
light sensor, spectrum meets C.I.E. photopic. Unit Range Resolution Accuracy
* High precision humidity sensor with fast response time. Lux 0 to 2,200 Lux 1 Lux ± 5% rdg ± 8 dgt
* Optional Pt 1000 ohm Temp. probe for the prcision 1,800 to 20,000 Lux 10 Lux
Temp. measurement. Ft-cd 0 to 204.0 Fc 0.1 Ft-cd
* Built- in microprocessor circuit assures excellent 170 to 1,860 Fc 1 Ft-cd
performance and accuracy. Remark : Ft-cd : feet candle
* Concise and compact buttons arrangement,
easy operation. Dew point Temp.
* Memorize the maximum and minimum value with recall.
* ℃/℉ detection by pressing button on the front panel. Unit Range Resolution Remark
* Hold function to freeze the current reading value
Sport/Weather meter nENVIRONMENT METER Model : SP-9202
11 in 1, Anemometer, Humidity meter, Barometer UV Light , Altitude, Pt 1000 Temp. ( optional )
GENERAL SPECIFICATIONS Ar flow
Display 8 mm LCD display
Measurement 1. Air velocty/Temp. Unit Range Resolution
2. Humidity/Temp. CMM 0.024 to 36000 0.001/0.01/0.1/1
3. UV Light CFM 0.847 to 1271300 0.001/0.01/0.1/1/10 (x10)/100 (x100)
4. Barometer
5. CFM, CMM
6. Dew point Dew point Temp.
7. Wet bulb
8. Wind chill Unit Range Resolution Remark
9. Heat index ℃ -25.3 to 49.0 ℃ 0.1 ℃ * Calculate from the
10. Altitude ℉ -13.5 to 120.0 ℉ 0.1 ℉ humidity/Temp. value
11. Pt 1000 ohm Temp.( optional ) Please refer to http://en.wikipedia.org/wiki/Dew_point
Operating Max. 80% RH.
Humidity Wet bulb Temp.
Operating 0 to 50 ℃ ( 32 to 122 ℉ )
Temperature Unit Range Resolution Remark
Over Input Indication of “- – – – ” ℃ -5.4 to 49.0 ℃ 0.1 ℃ * Calculate from the
Display ℉ 22.2 to 120 ℉ 0.1 ℉ humidity/Temp. value
Power Supply CR 2032 DC 3V battery Please refer to http://en.wikipedia.org/wiki/Wet-bulb_temperature
Power Approx. DC 5 mA
Consumption Heat index
Weight 160g (battery included)
Dimension HWD 120 x 45 x 20 mm (4.7 x 1.8 x 1.2 inch). Unit Range Resolution Accuracy
Standard Instruction Manual ℃ 0 to 100.0 ℃ 0.1 ℃ ± 2.0 ℃
Accessory ℉ 32 to 212 ℉ 0.1 ℉ ± 3.6 ℉
Optional Pt 1000 ohm Temp. probe, TP-1000
Sport/Weather meter ENVIRONMENT METER Model : SP-9201
11 in 1, Anemometer, Humidity meter, Barometer Light Meter, Altitude, Pt 1000 Temp. ( optional )
GENERAL SPECIFICATIONS CMM 0.024 to 36000 0.001/0.01/0.1/1
Display 8 mm LCD display CFM 0.847 to 1271300 0.001/0.01/0.1/1/10 (x10)/100 (x100)
Measurement 1. Air velocty/Temp.
2. Humidity/Temp. Dew point Temp.
3. Light
4. Barometer Unit Range Resolution Remark
5. CFM, CMM ℃ -25.3 to 49.0 ℃ 0.1 ℃ * Calculate from the
6. Dew point ℉ -13.5 to 120.0 ℉ 0.1 ℉ humidity/Temp. value
7. Wet bulb Please refer to http://en.wikipedia.org/wiki/Dew_point
8. Wind chill
9. Heat index Wet bulb Temp.
10. Altitude
11. Pt 1000 ohm Temp.( optional ) Unit Range Resolution Remark
Operating Max. 80% RH. ℃ -5.4 to 49.0 ℃ 0.1 ℃ * Calculate from the
Humidity ℉ 22.2 to 120 ℉ 0.1 ℉ humidity/Temp. value
Operating 0 to 50° C (32 to 122° F) Please refer to http://en.wikipedia.org/wiki/Wet-bulb_temperature
Temperature
Over Input Indication of “- – – – ” Heat index
Display
Power Supply CR 2032 DC 3V battery Unit Range Resolution Accuracy
Power Approx. DC 5 mA ℃ 0 to 70.0 ℃ 0.1 ℃ ± 2.0 ℃
Consumption ℉ 32 to 158 ℉ 0.1 ℉ ± 3.6 ℉
Weight 160g (battery included) Pleas refer to http://en.wikipedia.org/wiki/Heat_index
Dimension HWD 120 x 45 x 20 mm (4.7 x 1.8 x 1.2 inch).
Standard Instruction Manual Effects of the heat index (shade values)
Accessory Celsius Fahrenheit Notes
Optional Pt 1000 ohm Temp. probe, TP-1000 27– 32