LCR meters

LCR METER Model No:LCR-9184

LCR-9184

LCR-9183

SMD TESTER, optional ModelSMDA-22

LCR-9173

SMD TEST CLIP, optionalModelSMDC-21

Description:
* Intelligent microprocessor circuit, professional.
* 19999/1999 counts dual LCD display
* Auto LCR smart check and measurement.
* Test range : (ex : F = 1 KHz)
L : 200.00 uH to 2000.0 H
C : 2000.0 pF to 2.000 mF
R : 20.000 to 200.0 M
* Series/Parallel modes are selectable.
* DCR mode 200.00 to 200.0M
* Five test frequency are available :
100 Hz/120 Hz/1 KHz/10 KHz/100 KHz
* Ls/Lp/Cs/Cp with D / Q / / ESR Parameter.
* LCD Display with backlight structure.
* Power : DC 9V battery or DC 9V adapter in.
* RS232/USB computer interface.
* Optional SMD test clips, SMDC-21.
* Optional SMD tester, SMDA-22.
* Optional USB cable, USB-01.
* Optional data acquisition software, SW-E803.
* Optional holster, HS-03.

LCR METER Model No:Model :LCR-9183

100 Hz120 Hz1 KHz10 KHz100 KHz, Professional

LCR-9183

LCR-9183

SMD TESTER, optional ModelSMDA-22

LCR-9183

HOLSTER ModelHS-03

LCR-9183

SMD TEST CLIP, optionalModelSMDC-21

FEATURES

* 19,999/1,999 counts dual LCD display. Resistance ( Rp/Rs )

* AutoLCR smart check and measurement.

* Serial/Parallel modes are selectable. Range Accuracy Accuracy Remark

* Ls/Lp/Cs/Cp with D/Q/θ /ESR parameters. 100 Hz/120 Hz 1000 Hz

* Support DCR mode 1.00 Ω to 200.0 MΩ . 20 Ω ± ( 1.2% + 5d ) ± ( 1.2% + 5d ) After Short CAL.

* Five different test frequency are available : 200 Ω ± ( 0.8% + 5d ) ± ( 0.8% + 5d )

100 Hz/120 Hz/1 KHz/10 KHz/100 KHz. 2000 Ω ± ( 0.8% + 5d ) ± ( 0.8% + 5d )

* Test AC signal level : 0.6 V rms typically. 20 KΩ ± ( 0.8% + 5d ) ± ( 0.8% + 5d )

* Test range : ( ex. F = 1 KHz ) 200 KΩ ± ( 0.8% + 5d ) ± ( 0.8% + 5d )

L : 200.00 uH to 2000.0 H 2000 KΩ ± ( 1.5% + 5d ) ± ( 1.5% + 5d ) After Open CAL.

C : 2000.0 pF to 2.000 mF 20 MΩ ± ( 1.5% + 5d ) ± ( 2.5% + 5d ) After Open CAL.

R : 20.000Ω to 200.0 MΩ 200 MΩ ± ( 2.5% + 5d ) ± ( 6% + 5d ) After Open CAL.

* Multi-level battery detector.

* RS232/USB PC Computer interface. Range Accuracy Accuracy Remark

* Can default auto power off. 10 KHz 100 KHz

20 Ω ± ( 1.2% + 5d ) ± ( 2.5% + 5d ) After Short CAL.

GENERAL SPECIFICATIONS 200 Ω ± ( 0.8% + 5d ) ± ( 0.8% + 5d )

Display LCD size56.4 X 52.9 mm. 2000 Ω ± ( 0.8% + 5d ) ± ( 0.8% + 5d )

Test frequency 100 Hz/120 Hz/1 KHz/10 KHz/100 KHz 20 KΩ ± ( 0.8% + 5d ) ± ( 0.8% + 5d )

Function L/C/R Function selector 200 KΩ ± ( 0.8% + 5d ) ± ( 0.8% + 5d )

Frequency selector 2000 KΩ ± ( 1.5% + 5d ) ± ( 3% + 5d ) After Open CAL.

D/Q/θ /ESR selector 20 MΩ ± ( 2.5% + 5d ) ——————- After Open CAL

Description:
* Function is same as the LCR-9184, but without LCD backlight structure, without sorting function
and the spec. accuracy is larger than LCR-9184.

LCR METER HOLSTER Model No:HS-03

Holster for DM-9960, DM-9961, LCR-9183 and LCR-9184.

4

Description:
Holster for DM-9960, DM-9961, LCR-9183 and LCR-9184

POCKET LCR METER

Model No:LCR-9063

17

Description:
POCKET LCR METER
Model : LCR-9063
* Pocket size, 13 mm LCD, Max. 1999.
* L- 5 ranges, 2 mH to 20 H. C-6 ranges, 2 nF to 200 F. R- 6 ranges, 200 ohm to 20 M ohm.
* Economical type.
* Size : 120 x 72 x 37 mm.

LCR METER

Model No:LCR-9083

18

Description:
LCR METER
Model : LCR-9083
* Inductance, Capacitance, Resistance, Diode.
* L : 5 ranges, 2mH to 20H.
C : 6 ranges, 2 nF to 200 F.
R : 6 ranges, 200 ohm to 20 M ohm.
* Size : 185 x 87 x 39 mm, 18 mm LCD.

SMD TEST CLIPS

Model No:TLSM-15

19

Description:
SMD TEST CLIPS
Model : TLSM-15
* The test clips used for measuring the SMD components (resistor, capacitor, inductor, diode..)
* Cable length : appro x 90 cm

SMD TESTER  Model : SMDA-22

SMDA-22


LCR METER Model : LCR-9173

100 Hz120 Hz1 KHz10KHZ

LCR-9173

LCR-9173

SMD TESTER, optional

ModelSMDA-22

LCR-9173

 

SMD TEST CLIP, optional

ModelSMDC-21

LCR-9173

Carrying case

( optional )

FEATURES

* 6000 counts ADC resolution. Capacitance ( Cp/Cs ) : D ≦ 0.1, 0.5V(rms)

* Dual power supply , Battery or AC/DC Adapter.

* High performance analog front end for impedance Range Accuracy Accuracy (Z) measurement. 100 Hz 120 Hz

* Support Z / DCR measurement for LCR mode. 600 pF ± ( 3.5% + 5d ) ± ( 3.5% + 5d )

* Four different test frequency are available : 6000 pF ± ( 2.5% + 5d ) ± ( 2.5% + 5d )

100 Hz/120 Hz/1 KHz/10 KHz for L/C/R measurement. 60 nF ± ( 2.0% + 5d ) ± ( 2.0% + 5d )

* Built-in simple DMM front end circuit to support 600 nF ± ( 2.0% + 5d ) ± ( 2.0% + 5d )

DCV / Freq. / Diode mode. 6000 nF ± ( 1.5% + 5d ) ± ( 1.5% + 5d )

* Test AC signal level : 0.5 V rms typically. 60 uF ± ( 1.5% + 5d ) ± ( 1.5% + 5d )

* Test range : ( ex. F = 1 KHz ) 600 uF ± ( 1.5% + 5d ) ± ( 1.5% + 5d )

L : 600.0 uH to 60.00 H 6000 uF ± ( 2.5% + 5d ) ± ( 2.5% + 5d )

C : 600.0 pF to 600.0 uF 10 mF ± ( 3.5% + 5d ) ± ( 3.5% + 5d )

R : 60.00Ω to 20.00 MΩ

* Low battery voltage detector. Range Accuracy Accuracy

* Min. source resistance : 120Ω typical. 1k Hz 10 kHz

* 6 ratio resistor range used for LCR mode. 600 pF ± ( 2.5% + 5d ) ± ( 2.0% + 5d )

* Support buzzer sound driver with driving pattern 6000 pF ± ( 2.0% + 5d ) ± ( 1.5% + 5d )

& frequency selectable. 60 nF ± ( 2.0% + 5d ) ± ( 1.5% + 5d ) 600 nF ± ( 1.5% + 5d ) ± ( 1.5% + 5d )

GENERAL SPECIFICATIONS 6000 nF ± ( 1.5% + 5d ) ± ( 1.5% + 5d )

Display LCD size:46.5 X 45.5 mm. 60 uF ± ( 1.5% + 5d ) ± ( 2.5% + 5d )

Test frequency 100 Hz/120 Hz/1 KHz/10 KHz 600 uF ± ( 2.5% + 5d )

MODE L/C/R L/C/R Function selector 6000 uF  Frequency selector 10 mF