Panel meters ( V, A, RPM, Hz, Temp. )

4-20 mA Controller/Alarm/Indicator

Model No:CT-2012 24V out

1

Description:
4-20 mA Controller/Alarm/Indicator
Model : CT-2012
* Input : 4-20 mA DC, linear.
* User can default the desired display value between -1999 to 9999
(decimal point can be selected to DP1, DP2, DP3) and all the preset
data will be saved into the memory circuit permanently.
* When CT-2012 cooperate LUTRON’s 4 to 20 mA transmitters, whole
system will become the high performance Controller/Alarm/Indicator
for following measuring functions : Humidity, Light, pH, Dissolved
Oxygen, Conductivity, Vibration, Pressure, Sound, Temperature, RPM,
Hz, Load cell (Weight, Force), Potential (Angle, Level). ACV, ACA, DCV,
DCA, WATT….
* Control output: 2 points (COM, NO).
* Alarm output: 2 points (COM, NO).
* DC 24V power supply output.
* RS232/USB computer interface.
* Power : 90 ACV – 264 ACV, 50/60 Hz.
* DIN size : 96 x 48 mm. Depth : 107 mm.

VOLT METER MODULE

Model No:DP-30

2

Description:
VOLT METER MODULE
Model : DP-30 (LCD)
* Range : 199.9 mV, 3 1/2 digits.
* DP-30 : 13 mm LCD, DC 9V Power.
* Size : 71 x 46 mm, Depth : 21 mm.

VOLT METER MODULE

Model No:DP-40

3

Description:
VOLT METER MODULE
Model : DP-40 (LED)
* Range : 199.9 mV, 3 1/2 digits.
* DP-40 : 13 mm red LED, DC 5V Power.
* Size : 71 x 46 mm, Depth : 21 mm.

PANEL METER (DC 4-20mA), 3 1/2 digits

Model No:DR-99420

4

Description:
PANEL METER(4-20 mA), 3 1/2 digits
Model : DR-99420
* 4-20 mA, build “zero VR” & “gain VR”, can match most kinds of transducers.
* 110/220/230 ACV power, 14 mm red LED.
* DIN size : 96 x 48 mm, Depth : 104 mm.

PANEL METER (ACA), 3 1/2 digits

Model No:DR-99ACA

5

Description:
PANEL METER(ACA), 3 1/2 digits
Model : DR-99ACA
* 199.9 AC A to 10 ACA, 6 ranges.
* Range can be adjusted by jumper wire.
* 110/220/230 ACV power, 14 mm red LED.
* DIN size : 96 x 48 mm, Depth : 104 mm.

PANEL METER (ACV), 3 1/2 digits

Model No:DR-99ACV

6

Description:
PANEL METER(ACV), 3 1/2 digits
Model : DR-99ACV
* 199.9 ACmV – 600 ACV, 5 ranges.
* Range can be adjusted by jumper wire.
* 110/220/230 ACV power, 14 mm red LED.
* DIN size : 96 x 48 mm, Depth : 104 mm.

PANEL METER (DCA), 3 1/2 digits

Model No:DR-99DCA

7

Description:
PANEL METER(DCA), 3 1/2 digits
Model : DR-99DCA
* 199.9 DC A – 10 DCA, 6 ranges.
* Range can be adjusted by jumper wire.
* 110/220/230 ACV power, 14 mm red LED.
* DIN size : 96 x 48 mm, Depth : 104 mm.

PANEL METER (DCV), 3 1/2 digits

Model No:DR-99DCV

8

Description:
PANEL METER(DCV), 3 1/2 digits
Model : DR-99DCV
* 199.9 DCmV – 600 DCV, 5 ranges.
* Range can be adjusted by jumper wire.
* 110/220/230 ACV power, 14 mm red LED.
* DIN size : 96 x 48 mm, Depth : 104 mm.

AC VOLTAGE CONTROLLER/MONITOR  Model: PAV-6068

11

Description:
* Measurement range (no cooperate with the external PT) :
ACV : 0 to 600 ACV, 40 to 400 Hz.
* True rms for ACV measurement.
* Voltage input can cooperate with the external PT (voltage transformer) to expend the
measurement range. The PT range can be adjusted with default.
* Control setting, Hi/Lo alarm setting.
* Control relay output, alarm relay output.
* Power : 90 ACV to 264 ACV, 50/60 Hz.
* RS232/USB computer interface.

PANEL TACHOMETER

Model No:DT-2240D

9

Description:
PANEL TACHOMETER
Model : DT-2240D
* 5 to 100,000 RPM (x 0.1 RPM, <1,000 RPM).
* Accuracy : ( 0.05% + 1 d ).
* 110/220/230 ACV power, 14 mm red LED.
* DIN size : 96 x 48 mm, Depth : 104 mm.

RPM CONTROLLER/MONITOR

Model No:DT-2240D

10

Description:
RPM CONTROLLER/MONITOR
Model : PDT-2250
* 5 to 100,000 RPM (0.1rpm, <1,000 rpm).
* Control setting, Hi/Lo alarm setting.
* Control relay output, alarm relay output.
* Power : 90 ACV to 264 ACV, 50/60 Hz.
* RS-232 computer interface.
* DIN size : 96 x 48 mm. Depth : 107 mm.
* Optional proximity sensor PX-01.
* Optional photo sensor PI-06.

PHOTO SENSOR for DT-2240D / PDT-2250

Model No:PI-06

11

Description:
PHOTO SENSOR (Photo Interrupter)
Model : PI-06
* Photo interrupter or the photo sensor for DT-2240D, PDT-2250, TR-RPM1A4.
* Power supply : DC 12V to 30V.
* 3 wires : Power, Signal and Ground.

PROXIMITY SENSOR for DT-2240D / PDT-2250

Model No:PX-01

12

Description:
PROXIMITY SENSOR
Model : PX-01
* DT-2240D, PDT-2250, TR-RPM1A4 sensor or position detect.
* Detectable Object : Metals object.
* Detecting distance : 4 mm.
* Power : 12-24 DCV, Out-12 DCV 100 mA.

PROXIMITY SENSOR for DT-2240D / PDT-2250

Model No:PX-02

 

13

Description:
PROXIMITY SENSOR, mini & round type
Model : PX-02
* Mini type proximity sensor.
* Dia. 6.4 mm x 42 mm (length).
* PNP, normal open. Sn. : 1.5 mm.
* Power : 10 to 55 VDC. Output : 150 mA.

PANEL HUMIDITY/TEMP. METER

Model No:PHT-3109

14

Description:
PANEL HUMIDITY/TEMP. METER
Model : PHT-3109
* Humidity : 10 to 95 %RH.
* Temperature : 0 to 60 oC.
* Resolution : 0.1 %RH, 0.1 degree.
* Humidity control setting, Temp. control setting.
* Humidity control relay output, Temp. control relay output.
* Power : 90 ACV to 264 ACV, 50/60 Hz.
* RS-232 computer interface.
* DIN size : 96 x 48 mm. Depth : 107 mm.
* Accessory included : Humidity/Temp. probe.

PH CONTROLLER/MONITOR

Model No:PPH-2108

16

Description:
PH CONTROLLER/MONITOR
Model : PPH-2108
* 0 to 14 pH x 0.01 pH.
* ATC (automatic temperature compensation).
* pH control setting, Temp. control setting.
* pH control relay output, Temp. control relay output.
* Power : 90 ACV to 264 ACV, 50/60 Hz.
* RS-232 computer interface.
* DIN size : 96 x 48 mm. Depth : 107 mm.
* Optional pH electrodes, ATC probe.

RS232 CONTROLLER/MONITOR

Model No:PRS-2321

17

Description:
RS232 CONTROLLER/MONITOR
Model : PRS-2321
* Cooperate the LUTRON instruments (build in the RS232 interface), the panel meter will show all the measuring value.
* U1 control setting, U2 control setting.
* U1 control relay output, U2 control relay output.
* U1, U2, U3 display.
* Power : 90 ACV to 264 ACV, 50/60 Hz.
* RS-232 computer interface.
* Interface cable UPCB-03 is included.
* DIN size : 96 x 48 mm. Depth : 107 mm.

AC CURRENT CONTROLLER/MONITOR

Model No:PAA-6069

10

Description:
* Measurement range (no cooperate with the external CT) :
ACA : 0 to 10 A, 40 to 400 Hz.
* True rms for ACA measurement.
* Current input can cooperate with the external CT (current transformer) suchas CT 1000/5A,
CT 100/5A …to expend the measurement range. The CT range can be adjusted with default.
* Control setting, Hi/Lo alarm setting.
* Control relay output, alarm relay output.
* Power : 90 ACV to 264 ACV, 50/60 Hz.
* RS232/USB computer interface.

POWER FACTOR CONTROLLER/MONITOR Model: PPF-6066

15

Description:
* Power factor Measurement range :
0.10 to 1.00 PF.
* Resolution : 0.01 PF (power factor).
* Signal input :
ACV : 0 to 600 ACV, 40 to 400 Hz.
ACA : 0 to 10 A, 40 to 400 Hz.
* Control setting, Hi/Lo alarm setting.
* Control relay output, alarm relay output.
* Power : 90 ACV to 264 ACV, 50/60 Hz.
* RS232/USB computer interface.

PRESSURE CONTROLLER/MONITOR Model No:PPS-9312

16

Description:
* Meter connects with 2, 5, 10, 20, 50, 100, 400 bar sensor, no calibration procedures are necessary
when changing a new sensor .
* Unit select : Bar, PSI, Kg/cm2, inch Hg, mm Hg, inch H2O, meter H2O, Atmosphere.
* Control setting, Hi/Lo alarm setting.
* Control relay output, alarm relay output.
* Power : 90 ACV to 264 ACV, 50/60 Hz.
* Cooperate with the 4-20 mA pressure input, sensor can be installed in the faraway position.
* DC 12V output, used for the power of pressure sensor.
* RS-232/USB computer interface.
* DIN size : 96 x 48 mm. Depth : 107 mm.
* Optional pressure sensor, TR-PS2W-XXBAR.
* Optional USB cable, USB-01.
* Optional data acquisition software, SW-U801-WIN, SW-E802.

TEMPERATURE CONTROLLER/MONITOR Model No:PTM-9957

17

Description:
* Temp. sensor : type K/J/T/E/R/S thermocouple, Pt 100 ohm.
* Type K range : -100 to 1300 oC, oC/oF.
Type J range : -100 to 1200 oC, oC/oF.
Type T range : -100 to 400 oC, oC/oF.
Type E range : -100 to 900 oC, oC/oF.
Type R range : 0 to 1700 oC, oC/oF.
Type S range : 0 to 1500 oC, oC/oF.
Pt 100 ohm range : -199 to 850 oC, oC/oF.
* Resolution : 0.1 degree (< 1000 degree)
1 degree (≥1000 degree)
* Control setting, Hi/Lo alarm setting.
* Control relay output, alarm relay output.
* Power : 90 ACV to 264 ACV, 50/60 Hz.
* RS-232/USB computer interface.
* DIN size : 96 x 48 mm. Depth : 107 mm.
* Optional type K probe : TP-01, TP-02A, TP-03, TP-04, TP-05.
* Optional Pt probe : TP-100B.
* Optional USB cable, USB-01.
* Optional data acquisition software, SW-U801-WIN, SW-E802.

APPARENT POWER CONTROLLER/MONITOR Model No:PVA-6067

18

Description:
* Measurement range (no cooperate with the external CT and the PT) :
VA : 0 to 6,000 VA.
ACV : 0 to 600 ACV, 40 to 400 Hz.
ACA : 0 to 10 A, 40 to 400 Hz.
* True rms for VA measurement.
* Current input can cooperate with the external CT (current transformer) such as CT 1000/5A,
CT 100/5A …to expend the measurement range. The CT range can be adjusted with default.
* Voltage input can cooperate with the external PT (voltage transformer) to expend the
measurement range. The PT range can be adjusted with default.
* Control setting, Hi/Lo alarm setting.
* Control relay output, alarm relay output.
* Power : 90 ACV to 264 ACV, 50/60 Hz.
* RS232/USB computer interface.

POWER CONTROLLER/MONITOR PWA-6065

19

Description:
* Measurement range (no cooperate with the external CT and the PT).
Watt : 0 to 6,000 Watt.
ACV : 0 to 600 ACV, 40 to 400 Hz.
ACA : 0 to 10 A, 40 to 400 Hz.
* True rms for WATT measurement.
* Current input can cooperate with the external CT (current transformer) such as CT 1000/5A,
CT 100/5A …to expend the measurement range. The CT range can be adjusted with default.
* Voltage input can cooperate with the external PT (voltage transformer ) to expend the
measurement range. The PT range can be adjusted with default.
* Control setting, Hi/Lo alarm setting.
* Control relay output, alarm relay output.
* Power : 90 ACV to 264 ACV, 50/60 Hz.
* RS232/USB computer interface.

PANEL METERS

DCV, DCA, ACV, ACA, 4-20 mA, Temp.

Model : DR-99TEMP

DR-99ACV, DR-99ACA

DR-99420, DR-99TEMP

DR-99TEMP